HomeProductsData center/tower/base stationAMB Series Monitoring Modules for Data Center BusbarsAMB100/AMB110 AC Series Data Center Busbar Monitoring Module

AMB100/AMB110 AC Series Data Center Busbar Monitoring Module

The AMB Smart AC Busbar Monitor is a new development for intelligent busbars. It consists of an infeed and a tap detection module and integrates functions for conventional power measurement, current monitoring, consumption detection, and control. It also features an online alarm function and enables independent offline operation. It monitors the temperature of the busbar interface in real time.

  • 2 potential-free contact inputs
  • 45–65 Hz
  • 3 x 220/380 VAC
  • DIN 35 mm

Product info

Technical data

type
Standard functions
Optional functions
AMB100-A
(1) Complete electrical measurements of a three-phase AC circuit, measurement of the 2nd to 63rd harmonics, 1 leakage current, 8-way temperature, 1-way humidity measurement, measurement of maximum demand, neutral current, measurement of the potential difference between the neutral line and the ground line, 2 digital inputs, 2 digital outputs
/W(LORA)
AMB100-A-P1
(2) Complete electrical measurements of three-phase AC circuits, measurement of the 2nd to 63rd harmonics, 1 leakage current, 8-fold temperature measurement, 1-fold humidity measurement, measurement of maximum demand, measurement of neutral conductor current, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply
AMB110-A
(1) Complete electrical measurements of three-phase AC circuits, measurement of the 2nd to 63rd harmonics, 1 leakage current, 8-fold temperature measurement, 1-fold humidity measurement, measurement of maximum demand, measurement of neutral conductor current, measurement of the potential difference between neutral conductor and earth conductor, 2 digital inputs, 2 digital outputs
AMB110-A-P1
(2) Complete electrical measurements of three-phase AC circuits, measurement of the 2nd to 63rd harmonics, 1 leakage current, 8x temperature, 1x humidity, measurement of maximum demand, measurement of neutral conductor current, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply
AMB120
8-way temperature
AMB10
Monitor; the front network port: AMB10(F); the rear network port: AMB10(B&DZ), can automatically display the voltage and current parameters  
AMB20
AMB20-1: Accessory used with AMB100/AMB110 for transferring network ports between intelligent bus start boxes and plug-in boxes.
AMB20-2: Accessory used with AMB100/AMB110 for transferring RS485 ports between intelligent bus start boxes and plug-in boxes between network ports.

Note 1: AMB: Busbar series; 100: for power supply cabinet; 110: for tap-off cabinet; 120: for temperature sensing; A: for AC system; P1: discrete auxiliary power supply

Note 2: The AMB10 display is optional. The display is divided into the front-connected AMB10(F) and the rear-connected AMB10(B&DZ). It displays voltage and current in an automatic cycle.

Note 3: An external magnetic antenna is available for the optional LORA function. The standard length is 2 m.

Note 4: Temperature sensors are available in two round-hole versions (12 mm and 8 mm) and a cylindrical version (6 mm). Each version includes yellow, green, red, and black sensors.

 

AMB100-A-□/AMB110-A-□
Measured parameters Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, 2nd–63rd harmonics, temperature, leakage
voltage Nominal value
3×220/380VAC
Area
±20%
overload 1 channel: 0-5 VDC
Storm
CT
AMB100-A:5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA
AMB110-A: 100A/20mA
Area
1%-120%
overload 1.2 times the rated current value continuously or 10 times the rated current value instantaneously per second
input frequency
45-65Hz
Measurement accuracy Voltage/Current: Class 0.2; Active power/energy: Class 0.5; Resting power/energy: Class 1; Temperature: ±1°C
Auxiliary power supply AMB100/110-A(/W): Triggering after receipt of the request signal
AMB100/110-A(/W)-P1: Follow the busbar voltage
Features Temperature detection
-20-150℃
Leakage
0-1A
Digital input 2 dry contact inputs
Digital output 2 relay outputs; contact capacity: 3A/30VDC, 3A/250VAC
communication
Via RS485/Modbus-RTU or LORA antenna
installation
Use a DIN35mm rail
Protection
IP20
degree of contamination
2
Environment Temperature / Humidity / Altitude Operating temperature: -20–60 °C
Storage temperature: -25–70 °C
Relative humidity: ≤ 93 %
Altitude: ≤ 2500 m
Security insulation The minimum insulation resistance between all terminals and conductive components of the housing is 100 MΩ.
dielectric strength When a voltage of 2 kV AC is applied between the voltage/current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage current shall be less than 2 mA and no breakdown or flashover shall occur within 1 minute.
Electromagnetic immunity Immunity to electrostatic discharge
Class 4
Electromagnetic RF immunity
Class 3
Immunity to transient bursts
Class 4
Surge resistance
Class 4

 

AMB120
Measurement accuracy
Temperature: ±1℃
Auxiliary power supply 220 V AC, discrete
Features Temperature detection
-20-150℃
communication
Via RS485/Modbus-RTU or LORA antenna
installation
Use a DIN35mm rail
Protection
IP20
degree of contamination 2
Environment
Temperature / Humidity / Altitude Operating temperature: -20–60 °C
Storage temperature: -25–70 °C
Relative humidity: ≤ 93 %
Altitude: ≤ 2500 m
Safety
insulation The minimum insulation resistance between all terminals and conductive components of the housing is 100 MΩ.
dielectric strength When a voltage of 2 kV AC is applied between the voltage/current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage current shall be less than 2 mA and no breakdown or flashover shall occur within 1 minute.
Electromagnetic immunity
Immunity to electrostatic discharge Class 4
Electromagnetic RF immunity Class 3
Immunity to transient bursts Class 4
Surge resistance Class 4

Product display