HomeProductsEnergy managementADL Series DIN Rail Energy MetersADL3000-E Three-phase multifunction DIN rail energy meter

ADL3000-E Three-phase multifunction DIN rail energy meter

The Acrel ADL3000-E is a smart meter designed for energy statistics and power management in power systems, industrial and mining enterprises, and institutions. It can detect the 31st harmonic, features switch input and output, supports remote signaling and control, and has an alarm output. RS485 communication interface with MODBUS-RTU is optional. The electricity meter is compatible with various control systems, SCADA systems, and energy management systems.

  • Measurement: Three-phase kWh (0.5S), active power, reactive power, current, voltage, harmonics, etc.
  • Rated voltage: 3 x 220/380 V, 3 x 57.7/100 V (3P4W); 3 x 380 V, 3 x 100 V (3P3W)
  • Rated current: 3 x 10(80) A; 3 x 1(6) A
  • Frequency: 45–65 Hz
  • Communication: RS485 (MODBUS-RTU) and infrared
  • Multi-Rate: Spike, Peak, Valley and Flat kWh
  • Additional functions: cable temperature measurement and DO/DI
  • Display: LCD (8 digits)
  • Dimensions: 127 x 88 x 70 mm (L x W x H)
  • Wiring: Three-phase, 4-wire; Three-phase, three-wire
  • Mounting: 35 mm DIN rail
  • Standards and certificates: UL, IEC, CE

Product info

●Communication: RS485 (Modbus-RTU)
●Rated voltages: AC 3 x 100V, 3 x 380V, 3 x 57.7/100V, 3 x 220/380V; 3 x 1(6) A, 3 x 10(80) A
●Accuracy: kWh: Class 0.5S; kVrah: Class 2
●Frequency: 45–65 Hz
●Display: 8-digit LCD display for U, I, P, Q, PF, kWh and other energy consumption, power measurement (999999.99 kWh)
●Pulse output: Pulse output kWh/kvarh

●Consumption: <10 VA (single phase)
●Mounting: DIN 35 mm
●Dimensions (L x W x H): 126.5 x 88 x 69.5 mm
●Mounting: DIN 35 mm
●Cycle: ≤ 0.5 s/d
●Starting current: Direct connection: 0.004 lb
●Connection via current transformer: 0.001 ln

Technical data

characteristics

Measurement of various electrical parameters

● Harmonics (2nd–31st voltage and current) – optional

● F (Frequency)

● U (three-phase voltage)

● I (three-phase current)

● kWh (three-phase positive kilowatt hours)

● kVarh (kilovar hours)

● P (power)

● Q (reactive power)

● S (apparent power)

● PF (Power Factor)

Multi-tariff/Flexible tariff

● 4 time zones

● 4 tariffs (peak, peak, flat, valley)

● 2 periods

● 14 periods per day

● Frozen data (last 48 months or last 90 days)

● Maximum demand and occurrence time

2-channel RS485 communication

● Protocol: MODBUS-RTU

● 1-channel RS485 or 2-channel RS485, both optional

3-channel temperature measurement

● Thermistor: NTC temperature sensor

● Measuring range: -40 °C to +125 °C

DO/DI switch

● 1 channel DO

● 1 channel DI

HMI for parameter setting

● Code

● Protocol

● Address

● Baud rate

● Parity

● All ads

Infrared communication for remote meter reading

● Integrated infrared communication

● Simple remote meter reading

● Optional connection options

● Direct connection to the meter

● Initial connection via CT.

Optional connection methods

● Direct connection with meter

● Initial connection via current transformer.

functional description

function

functional description

provide function

Measurement of kWh

Active kWh (positive and negative)

Reactive kWh (positive and negative)

A, B, C phase positive active kWh

Measurement of electrical parameters

U、I、P、Q、S、PF、F

Measurement of harmonics

2~31ST voltage and current harmonics

□Note 1

LCD display

8-bit LCD display, backlight

Key programming

4 buttons for communication and parameter setting

Pulse output

Active pulse output

Reactive pulse output

□Note 2

Clock pulse output

□Note 2

Multi-tariff and functions

Active switching input

□Note 3

Switching output

□Note 2

Customization of 4 time zones, 2 time interval lists, 14 time intervals per day and 4 tariffs

Max required kWh and time passed

Frozen data from the last 48 months and the last 90 days

Date, time

communication

Infrared communication

The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU

The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU

□Note 3

Temperature measurement

Supports 3 outputs NTC temperature

□Note 4

“■” means standard, “□” means optional.

specification

3 phases 3 wires, 3 phases 4 wires

voltage

Reference voltage

3×100V、 3×380V、3×57.7/100V、 3×220/380V

consumption

<10VA(Single phase)

Impedance

>2MΩ

Accuracy class

Error ±0.2 %

Electricity

Input current

3×1(6)A (second connection with three-phase load line via additionally selected current transformers)
3×10(80)A (direct connection with three-phase load line via current transformers built into the ADL3000-E)

consumption

<1VA(single-phase rated current)

Accuracy class

Error ±0.2 %

Performance

Active, reactive, apparent power, error ±0.5℅

 frequency

45~65Hz, error ±0.2 %

temperature

-40℃~99℃

energy

Active energy (accuracy class: 0.5, 1), reactive energy (accuracy class 2)

Clock

≤0.5s/d

Energy pulse output

1 active optocoupler output, 1 reactive optocoupler output

Switching output

1 switching output

Switching input

1 optocoupler input

Pulse width

80±20ms

pulse constant

6400imp/kWh, 400imp/kWh (corresponds to the base current)

Interface and communication

RS485: Modbus RTU

Communication address area

Modbus RTU: 1~ 247

baud rate

1200bps~19200bps

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)

Product display

similar products