ADL400M Series Dual-Circuit Energy Meter with External Current Transformer
The ADL200M/400M series dual-circuit energy meter with external current transformer is an intelligent measuring device specifically designed for new energy generation systems such as grid-connected photovoltaic systems, micro-inverter systems, energy storage systems, and AC coupling systems. It is characterized by high precision, compact design, fast response times, and easy installation.
Product info
Technical data
| function | Descriptions |
| Measurement of electrical energy | Active energy measurement (forward and backward) |
| Reactive energy measurement (forward and reverse) | |
| Split-phase energy | |
| Electrical quantity measurement | U, I |
| P, Q, S, PF, F | |
| communication | RS485: Modbus RTU |
| Item | Performance parameters | |||
| Model series | ADL200M | ADL400M | ||
|
measurement |
Grid | Single-phase | Three-phase, four-wire | |
|
voltage |
(Unom) Nominal voltage | 230V | 3×230/400V | |
| input area | 0.8Unom ~ 1.2Unom | |||
| Overload | 1.2-fold rating (continuous) 2
2x rating for 1 second |
|||
| Power consumption | <2W, <10VA | |||
| Accuracy class | Error ±0.5% | |||
|
Electricity |
Minimum current (Imin) | 0.3A | ||
| Transient current (Itr) | 1.5A | |||
| Base current (Ib) | 30A | |||
| Maximum current (Imax) | D16:Imax = 120A | |||
| Short-term overcurrent | 30 times the maximum current for 20 ms | |||
| Power consumption | <1W, <1VA | |||
| Accuracy class | Error ±0.5 % | |||
| power | Active, reactive, and apparent power, error ±0.5℅ | |||
| Mains frequency | 50Hz, error ±0.5 % | ||
| Response rate | 50ms (voltage, current, power) | ||
| Installation category | CAT III | ||
| Overvoltage level | OVC III | ||
| measurement | Active electrical energy | Class 1 or B | |
| Electromagnetic compatibility | E2 | ||
|
Security |
Power frequency withstand voltage | Between communication and signal input, AC3kV 1min | |
| Insulation resistance | Input and output connections to the housing > 100 MΩ | ||
|
communication |
RS485 interface |
Modbus RTU protocol; Address: 1~247; Baud rate: 1200 bps - 38400 bps |
|
|
Environment |
Operating temperature range | -25℃~+55℃ | |
| Operating temperature range | -40℃~+70℃ | ||
| Storage temperature | -40℃~+85℃ | ||
|
Relative humidity |
≤95% (without condensation)
“Not suitable for humid environments” |
||
|
Height |
≤2000m | ||
|
IP protection class |
IP20 on terminal block without protective housing and IP51 in protective housing according to IEC 60529 |
||
| Pollution Degree | II | ||
| UC Degree | III | ||
| installation environment | Interior | ||
| Degree of protection | Class II (double insulation) | ||
| Usage environment | Mounted in the cabinet (the outer shell must not be touched) | ||
| Usage environment | M1 | ||
| Safety features of the transformer | Insulation resistance: greater than 1000 MΩ under normal conditions | ||