DC monitoring device for solar strings | |
Measurement: | DC current of up to 24 circuits (with Hall sensors); busbar voltage |
Communication: | RS485 (MODBUS RTU) |
Max. insulation measurement: | DC 20A or 30A |
Measuring the maximum voltage of the bus: | DC 1.5KV |
Temperature monitoring: | internal temperature of the PV Combiner Box |
DI function: | 3-channel digital input |
Advertisement: | LED display |
Installation: | 35 mm DIN rail (main body); perforation (cable) |
Power supply: | DC 24V or DC 1500V |
Application: | Coupled with PV Combiner Box for monitoring DC multi-circuits |
AGF-M Series DC Monitoring Device for Solar Strings
AGF-M perforation type PV confluence detection device is specially designed for intelligent PV combiner box. It is used to monitor the working status of solar modules in solar cell arrays, measure the currents of solar cells, detect the status of surge protection devices and DC breakers. The device is equipped with RS485 (Modbus) communication port, where all data can be transmitted to the master device. Acrel AGF-M solar DC string monitoring device measures DC current in up to 24 circuits (with Hall sensors); busbar voltage, paired with PV combiner box to monitor DC multi-circuits
Product info
Technical data
Model | AGF-M4T |
AGF-M8T |
AGF-M12T | AGF-M16T | AGF-M20T | AGF-M24T |
input channels |
4 |
8 |
12 |
16 |
20 |
24 |
Rated current | DC 0~30A | |||||
reaction time | 1s | |||||
accuracy | class 0.5 | |||||
temperature coefficient | 400ppm | |||||
RS485 communication | RS485/ModBus-RTU protocol, 4800/9600/19200/38400bps | |||||
additional function | ||||||
Switching input | 3-way input (optocoupler or dry contact mode) | |||||
General Technical Parameters | ||||||
temperature/humidity |
Working temperature: -35~+65℃ Humidity 95%, no condensation, no corrosion gas *Working temperature of the display module:-20~+70℃ |
|||||
temperature measurement function | To measure the internal temperature of the box (-20℃~100℃) | |||||
Height |
≤3000m |
|||||
insulation resistance |
≥100MΩ |
|||||
withstand voltage for industrial frequencies | Power/Communication/Switch Input/Cell Voltage Input--AC 2kV/1min (When the auxiliary power supply is DC1500V, the withstand voltage between the power supply, the photocell input and other circuits is AC 2.7kV) Current input/power, cell voltage, communication, switching condition--AC3.5kV/1min |
Multi-circuit measurement of up to 24 DC circuits
|
![]() |
3-channel DI switch status monitoring
|
![]() |
temperature measurement and overtemperature alarm function
|
![]() |
HMI keyboards for programming
|
![]() |
LCD display module
|
![]() |
Easy installation
|
![]() |
Product display
Downloads
Video
similar products