AC multi-circuit energy meter | |
12 or 24 channels of each branch circuit of A+B | |
Independent 2-circuit of the output current | |
1 RS485 communication | |
potency, reactivity | |
2nd-31st harmonic | |
A+B Independent branch circuits: | [24 or 48] (total) |
Frequency: | 45~60Hz |
Installation: | DIN rails 35 mm |
Dimension (L*W*H): | 180*94.3*45mm |
Power supply by AMC16Z-ZA; DC 12-24V when used alone |
AMC16Z-FAK24/48 AC multi-circuit energy meter
Acrel AMC16Z-FAK series can monitor the complete power parameters and switching status of 24 or 48 branches of dual-channel AC outlet, 1-channel RS485 communication and phase matching. AMC16Z-FAK24 and AMC16Z-FAK48 are widely used for precise power distribution monitoring equipment in data centers.
Product info
Technical data
product models
AMC16Z-ZA | A+B independent 2-channel three-phase input U, 1, P, Q, S, PF, EP, EQ, UN to PG, neutral current 2-63rd harmonic voltage and current 6-channel passive switch input 2-channel switch output RS485 (Modbus RTU) communication |
AMC16Z-ZD | Measuring voltage and current of A+B independent bidirectional DC bus Kw、Kwh、6DI+2DO+1 RS485(Modbus-RTU) |
AMC16Z-KA | A+ B independent 2-way one-sidedness 24 active switching states |
AMC16Z-KD | A+ B independent 2-way single-sided 24-pole switching state |
AMC16Z-FAK24 | Measurement of A+B two-way AC socket, total 24 branches fully electrical parameters and switching value status, 1RS485 (Modbus-RTU) |
AMC16Z-FAK48 | Measurement of A+B two-way AC socket, total 48 branches full electrical parameters and switching value status, 1RS485 (Modbus-RTU) |
AMC16Z-FDK24 | Measure A+B two-way DC output, total 24 branches fully electrical parameters and switching value/status, 1RS485(Modbus-RTU) |
AMC16Z-FDK48 | A+B two-way DC output measurement, total 48 branches fully electrical parameters and switching value status, 1RS485 (Modbus-RTU) |
product features
monitoring of dual AC output circuits ● A + B monitoring of the two-sided independent AC circuits ● Complete monitoring of electrical parameters ● Multi-metering for outgoing branch circuits |
![]() |
measurement of multiple circuits ● Both 1-phase and 3-phase measurement ● Max. 36 single-phase circuits ● Max. 12 3-phase circuits ● Mixed: 8 circuits, 3-phase and 12 circuits, 1-phase, for example |
![]() |
analysis of network quality ● 2nd ~ 31st harmonic ● Total harmonics |
![]() |
Turn status detection on/off ● A+B on both sides ● 48-channel DI (digital input) |
![]() |
Technical parameters
Model |
AMC16Z-FAK24 |
AMC16Z-FAK48 |
measurement parameters |
Voltage, current, frequency, active power, reactive power, power factor, switching state |
|
2nd ~ 31st harmonic | ||
nominal voltage of the bus |
AC 220V(±20%) | |
current output circuit |
Nominal value |
50mA |
Area | 0.125-60mA | |
Measurement accuracy |
Outgoing line | Voltage/Current/Active Power/Active Energy Level 0.5, Reactive Power/Reactive Energy Level 1 |
input frequency |
45~60Hz | |
Auxiliary power supply | Power supply by AMC16Z-ZA; DC 12-24V when used alone | |
Environment | temperature |
Working temperature: -15 °C ~ 55 °C Storage temperature: -25 °C ~ 70 °C |
moisture | Relative humidity≤93% | |
Height | ≤2500m | |
communication | RS485/Modbus-RTU | |
installation method | DIN35mm guide rail or base plate mounting | |
IP protection class | IP20 | |
pollution class | 2 | |
Security | insulation | All terminals and the insulation resistance between the conductive pieces not less than 100 MΩ |
dielectric strength | A-channel switch input signal // B-channel switch input signal // other ports meet AC2kV 1 minute between pairs, leakage current should be less than 2mA, no breakdown or flashover | |
Electromagnetic compatibility | Antistatic interference | level 4 |
Resistance to radiation from high-frequency electromagnetic waves | level 3 |
Product display
Downloads
Video
similar products