AMC72L-AI Single Phase Programmable AC Ammeter

AMC series meters adopt AC sampling technology, which can measure the current, voltage, power, power factor and electric energy parameters in the power grid separately. It can adjust the magnification through the panel membrane switch. The meters have an RS485 communication interface with Modbus protocol and can convert the current signal into a standard DC analog signal.

  • Single-phase current meter
  • LCD display
  • RS485 and Modbus RTU protocols
  • Input AC 1A or 5A

Product info

Single-phase AC ammeter
Communication:RS485(Modbus RTU)
Advertisement:LCD display, set multiplier power
Rated current:AC current: AC1A, 5A
Measurement accuracy:Active energy: Class 0.5
Installation:Panel mounted
Alarm output (optional):DC 30V/3A; AC 250V/3A
Analog output (optional):DC 4~20mA
DI/DO function (optional):2-channel DI and 2-channel DO
Dimension (LBH):Panel size (L×W): 75*75mm
Cutout(L×W): 67*67mm
Depth (H): 94.3mm
Consumption:Power consumption: Power consumption< 0.5VA;
Auxiliary power supply: Power consumption≤5VA
Auxiliary power supply:AC/DC 85-265V

Technical data

Technical data Value
Entrance Nominal value AC voltage: Single phase AC 100V,400V
Three-phase AC 100V, 400V, 660V (UL-L, 72/ 96 only)
Alternating current:AC1A,5A;
Overload Voltage: 1.2 times nominal value (continuous); 2 times nominal value /1 second
Current: 1.2 times nominal value (continuous); 10 times nominal value /1 second
frequency 45Hz~65Hz
Power consumption The power consumption of each voltage and current input circuit is less than 0.5VA
accuracy Class 0.5
function Advertisement LED or LCD
communication RS485, Modbus RTU protocol;(1 start bit, 8 data bits, 1 stop bit, no parity)
Baud rate 2400/4800/9600/19200 bps etc.
alarm 1 channel passive relay, contact capacity 3A/30VDC, 3A/250VAC, used for high, low, unbalance alarm, etc.
Analogous DC4~20mA, (load <500Ω)
(Note: Shielded cable is specially selected for the above signal inputs and outputs)
Switch Input: 4-channel or 2-channel dry contact input, built-in power supply
Output: 2-channel switching output, NO relay contact, capacity: 3A/30VDC, 3A/250VAC
Auxiliary power supply  AC/DC 85-265V
Power consumption <5VA
Insulation resistance  ≥ 100MΩ
Mains frequency withstand voltage Between the power supply terminal set and the signal input, the output terminal set 2kV/1min (RMS)
Between the housing and all connection sets (except those with a reference voltage of less than 40V) AC 4kV
Vicinity temperature Operating: -10℃~+55℃Storage: -25°C ~+70°C
humidity ≤95%RH, no condensation, no corrosive gas
Altitude ≤ 2500m