HomeProductsEnergy monitoring and protectionAMC Series Programmable Power MetersAMC72L-DI Single Phase Programmable DC Ammeter

AMC72L-DI Single Phase Programmable DC Ammeter

AMC72L-DI is an intelligent meter designed for power supply monitoring of power systems, industrial and mining enterprises, public facilities and intelligent buildings. It can measure DC signals with RS485/MODBUS-RTU protocol; with switch input and relay output, it can realize the functions of "remote signaling" and "remote control" of circuit breaker. It has LCD display interface and allows parameter setting and control through panel buttons, which is very suitable for real-time power monitoring system. Acrel AMC series AC ammeter and voltmeter adopts AC sampling technology and can directly measure current and voltage of three-phase network. It can be used for local display and connection of industrial control equipment to form a measurement control system.

  • DC Single-phase current meter
  • LCD display
  • RS485 and Modbus RTU protocols
  • Input 5 A DC (direct connection); 0/4 ~ 20 mA DC (via DC sensor); 75 mV (via shunt)
  • accuracy 0.5
  • Standard and certificate: CE

Product info

Single-phase DC ammeter
Communication:RS485(Modbus RTU)
Advertisement:LCD display, set multiplier power
Rated current:5 A DC (direct connection); 0/4 ~ 20 mA DC (via DC sensor); 75 mV (via shunt)
Measurement accuracy:Active energy: Class 0.5
Installation:Panel mounted
Dimension (LBH):Panel size (L×W): 75*75mm
Cutout(L×W): 67*67mm
Depth (H): 94.3mm
Analog output (optional):DC 4~20mA
Alarm output (optional):DC 30V/3A; AC 250V/3A
DI/DO function (optional):2-channel DI and 2-channel DO
Consumption:Power consumption: Power consumption< 0.5VA;
Auxiliary power supply: Power consumption≤5VA
Auxiliary power supply:AC/DC 85-265V

Technical data

Technical data Value
Entrance Nominal value DC input: 5 A DC (direct connection); 0–20 mA or 4–20 mA DC (via DC sensor); 75 mV DC (via shunt)
Overload Voltage: 1.2 times nominal value (continuous); 2 times nominal value /1 second
Current: 1.2 times nominal value (continuous); 10 times nominal value /1 second
frequency 45Hz~65Hz
Power consumption The power consumption of each voltage and current input circuit is less than 0.5VA
accuracy Class 0.5
function Advertisement LCD
communication RS485, Modbus RTU protocol;(1 start bit, 8 data bits, 1 stop bit, no parity)
Baud rate 2400/4800/9600/19200 bps etc.
alarm 1 channel passive relay, contact capacity 3A/30VDC, 3A/250VAC, used for high, low, unbalance alarm, etc.
Analogous DC4~20mA, (load <500Ω)
(Note: Shielded cable is specially selected for the above signal inputs and outputs)
Switch Input: 4-channel or 2-channel dry contact input, built-in power supply
Output: 2-channel switching output, NO relay contact, capacity: 3A/30VDC, 3A/250VAC
Auxiliary power supply  AC/DC 85-265V
Power consumption <5VA
Insulation resistance  ≥ 100MΩ
Mains frequency withstand voltage Between the power supply terminal set and the signal input, the output terminal set 2kV/1min (RMS)
Between the housing and all connection sets (except those with a reference voltage of less than 40V) AC 4kV
Vicinity temperature Operating: -10℃~+55℃Storage: -25°C ~+70°C
humidity ≤95%RH, no condensation, no corrosive gas
Altitude ≤ 2500m