multi-circuit energy meter | |
Rated voltage and current: | AC 3*220/380V, 5A, 100A |
Measurement accuracy: | Active power: Class 1 Reactive power: Class 2 |
Frequency: | 50~60Hz |
Pulse output: | Active pulse output and reactive pulse output |
Consumption: | <0.5VA (single phase) |
Wireless communication: | RS485 interface, Modbus RTU protocol; baud rate 1200~38400, LoRa(470MHz) |
Dimensions (L*W*H): | 72*97.7*36 mm |
Starting current: | 4‰lb |
Installation: | 35mm |
DTSD1352-4S multi-circuit energy meter
Acrel DTSD1352-4S series DIN rail multi-circuit power meter is mainly used for complete electrical parameter measurement of multiple circuits, and can be connected to the power input of 4 three-phase circuits or 12 single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor, phase angle, unbalance and harmonics.
Product info
Technical data
Auxiliary power supply | AC/DC 85~265 V or DC 40-60 V; Power consumption ≤ 10 VA | |
input signal | frequency | 45~65 Hz |
Tension | Nominal value: AC 3×220 V/380 V | |
Overload: 1.2 times rated value (continuous); 2 times rated value/1 second | ||
Power consumption: ≤ 0.5 VA (each channel) | ||
Electricity | Nominal value: Rated current of secondary input: 50 mA | |
Overload: 1.2 times rated value (continuous); 10 times rated value/1 second | ||
Power consumption: ≤ 0.5 VA (each channel) | ||
Measurement accuracy | Frequency: 0.05 Hz, Voltage and current: 0.5 class, Active energy: 1 class, Reactive energy: 2 class; Accuracy 2nd to 31st harmonic: ±1 % | |
function | Pulse output | Output method: open collector optocoupler pulse, the pulse constant is 400 imp/kWh by default (and active open input can only be either or.) |
communication | RS485 interface, Modbus RTU protocol; baud rate 1200~38400 | |
Switching input | 2-way or 4-way passive dry contact input, built-in power supply; 2-way active wet node input (AC220V), oil generator identification and grid access (and pulse output can only be either or.) |
|
Switching output | Output method: relay normally open contact output; Contact power: AC 250V/3A DC 30V/3A |
Security | dielectric strength | >AC 2 kV/1 min |
Insulation resistance | Input and output connections to the housing >100 MΩ | |
Vicinity | Operating temperature: -20 °C to +60 °C Storage temperature: -40 °C to +70 °C Relative humidity: ≤ 95 %, no condensation Altitude: ≤ 2500 m |
|
Electromagnetic | Tolerability: better than class 3 |
matching transformers
The current transformer is a crystal head interface, the primary current is 50A-600A. If the current transformer is different, the customer can change the current transformation ratio through the instrument interface or communication according to the actual use. The transformer is shown in Figure 1 and Figure 2. | ![]() |
type | Relationship | line length | accuracy |
AKH-0.66/W-9NY 50A/20mA | 50A/20mA | (1+0.2)m | 0.2 class |
AKH-0.66/K-Φ10N 50A/20mA |
50A/20mA | (1+0.2)m | 0.5 class |
AKH-0.66/W-12NY 100A/50mA |
100A/50mA | (1+0.2)m | 0.2 class |
AKH-0.66/K-Φ16N 100A/50mA |
100A/50mA | (1+0.2)m | 0.5 class |
AKH-0.66/W-20Y 200A/50mA |
200A/50mA | (1+0.5)m | 0.2 class |
AKH-0.66/K-Φ24N 200A/50mA |
200A/50mA | (1+0.5)m | 0.5 class |
AKH-0.66/W-30NY 250A/50mA |
250A/50mA | (1+0.5)m | 0.2 class |
AKH-0.66/K-Φ24N 250A/50mA |
250A/50mA | (1+0.5)m | 0.5 class |
AKH-0.66-TD-Φ60-NY |
400A/50mA | (1+0.5)m | 0.2 class |
AKH-0.66/K-Φ36N 400A/50mA |
400A/50mA | (1+0.5)m | 0.5 class |
AKH-0.66-TD-Φ60-NY |
600A/50mA |
(1+0.5)m | 0.2 class |
AKH-0.66/K-Φ36N 600A/50mA |
600A/50mA | (1+0.5)m | 0.5 class |
Product display
Downloads
Video
similar products