GGF Medical Isolation Power Supply Cabinet
The medical isolation distribution cabinet is a cabinet for local IT systems designed to meet the requirements of medical power supply group II. An insulation monitoring device installed in the IT system monitors the system's insulation status. Each output circuit is equipped with a short-circuit breaker, and the output circuit in the TN-S system is equipped with a residual current device. The products are divided into three-phase isolated power supply cabinets of the GGF-O series and single-phase isolated power supply cabinets of the GGF-I series. Depending on the number of input voltage phases, these products meet the safety and reliability requirements of various operating rooms and intensive care units and comply with IEC standards.
Product info

Technical data
|
Use of cold-rolled steel sheet Q235A ● Class A ● Over +40 °C |
![]() |
|
fan ● Louvered fan ● Low noise level |
![]() |
|
Different types of installation ● Wall installation ● Floor mounting ● Split assembly |
![]() |
|
Configuration/Model
|
GGF-O6X
|
GGF-O8X
|
GGF-O6XL
|
GGF-O8XL
|
Notice |
| Isolation transformer | AITR6300 | AITR8000 |
AITR6300
|
AITR8000
|
|
| Switchgear with double power |
Optional configuration
|
||||
| Insulation monitor |
AIM-M100 (AIM-M10)
|
AIM-M200
|
IT systems | ||
| Test signal generator |
—
|
ASG150
|
|||
| Insulation fault locator | — | AIL150-8 | |||
| DC power supply | ACLP10-24 | HDR-60-24 | |||
| Power converter |
AKH-0.66 40I 75/5、AKH-0.66P26
|
||||
| circuit breaker |
iC60LMA 40A/2P、iC60LMA 16A/2P、iC60LMA 20A/2P
|
||||
| Alarm and display instrument |
AID120(AIM-M100)/AID10(AIM-M10)
(installed next to the Intelligence Panel)
|
AID150
(installed next to the Intelligence Panel)
|
|||
| Supply circuits |
8 × AC220V
|
TN systems | |||
|
1 x AC380V, 8 x AC220V
|
|||||
| Overvoltage protection |
PR20 20KA 3P+N
|
||||
| Multifunction measuring device |
DTSD1352
|
||||
|
Residual current protective devices
|
Operating current ≤ 30 mA (Type A) | ||||
| Technical parameters |
GGF-IXG
|
GGF-IXQ
|
GGF-IXF
|
GGF-OXG
|
GGF-OXQ
|
GGF-OXF
|
| nominal voltage |
220V AC
|
380V/220V AC
|
||||
| Nominal capacity |
3.15/5/6.3/8/10kVA
|
— |
3.15/5/6.3/8/10
|
—
|
||
| Nominal frequency |
50/60Hz
|
|||||
| distribution circle | IT systems: 4 or 5 AC220V (can be customized) | IT systems: 8 AC220V (can be customized) | ||||
|
—
|
TN-S systems: 1 AC380V, 8 AC220V | |||||
| Protection level |
IP31
|
IP34D
|
IP31
|
IP34D
|
||
| installation |
Floor-standing devices
|
Embedded | Floor-standing devices | Embedded | ||
| Inlet and outlet | Below | There are access lines both below and above | Floor inlet and floor outlet | There are access lines both below and above | ||
| Communication | RS485 interface, Modbus RTU protocol | |||||