{"id":658,"date":"2023-11-03T16:46:42","date_gmt":"2023-11-03T08:46:42","guid":{"rendered":"http:\/\/acrel-electric.de\/?p=658"},"modified":"2023-11-13T16:26:25","modified_gmt":"2023-11-13T08:26:25","slug":"acrel-dc-energiezahler-in-pv-anlagen-in-singapur","status":"publish","type":"post","link":"https:\/\/www.acrel-electric.de\/en\/acrel-dc-energiezahler-in-pv-anlagen-in-singapur\/","title":{"rendered":"Acrel DC energy meters in PV systems in Singapore"},"content":{"rendered":"<p class=\"has-medium-font-size\"><font style=\"vertical-align: inherit;\"><font style=\"vertical-align: inherit;\">This article describes the application of the Acrel DC meter in a photovoltaic system in Singapore. The device measures current, voltage and energy as well as the shunt.<\/font><\/font><\/p>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-large-font-size\"><strong>Project overview<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\">This company is based in Singapore and is the photovoltaic system installation company in Singapore. Mainly uses DC energy meter DJSF1352-RN and shunt, used to measure and monitor current and voltage in a PV system.<\/p>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-large-font-size\"><strong>DJSF1352-RN Series DC Energy Meter<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\">DJSF1352-RN series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations and charging piles. This series of devices can measure voltage, current, power, forward and reverse power in a DC system. It can be used for local display and connected with industrial control equipment and computers to form a measurement and control system. And it has a variety of external excuse functions for the user to choose, RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input\/output. According to the different requirements, through the instrument panel buttons, you can set the ratio, communication parameters. The product meets the relevant technical requirements of the standard Q\/GDW1825-2013 DC power meter specification, GB\/T29318-2012 non-vehicle charging electric energy measurement for electric vehicles, Q\/GDW364-2009 single-phase energy meter specification.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"554\" height=\"509\" src=\"http:\/\/acrel-electric.de\/wp-content\/uploads\/2023\/11\/dc-digital-multifunction-meter.webp\" alt=\"\" class=\"wp-image-735\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/dc-digital-multifunction-meter.webp 554w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/dc-digital-multifunction-meter-300x276.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/dc-digital-multifunction-meter-13x12.webp 13w\" sizes=\"auto, (max-width: 554px) 100vw, 554px\" \/><\/figure><\/div>\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-large-font-size\"><strong>wiring<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"446\" height=\"207\" src=\"http:\/\/acrel-electric.de\/wp-content\/uploads\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe.webp\" alt=\"\" class=\"wp-image-736\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe.webp 446w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe-300x139.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe-18x8.webp 18w\" sizes=\"auto, (max-width: 446px) 100vw, 446px\" \/><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"244\" src=\"http:\/\/acrel-electric.de\/wp-content\/uploads\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe2.webp\" alt=\"\" class=\"wp-image-737\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe2.webp 449w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe2-300x163.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/DJSF1352-RN\u7ed3\u6784\u56fe2-18x10.webp 18w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure><\/div>\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-large-font-size\"><strong>Photos on site<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"491\" src=\"http:\/\/acrel-electric.de\/wp-content\/uploads\/2023\/11\/\u73b0\u573a\u7167\u7247.webp\" alt=\"\" class=\"wp-image-738\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/\u73b0\u573a\u7167\u7247.webp 800w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/\u73b0\u573a\u7167\u7247-300x184.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/\u73b0\u573a\u7167\u7247-768x471.webp 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/ankerui\/2023\/11\/\u73b0\u573a\u7167\u7247-18x12.webp 18w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-large-font-size\"><strong>Summary<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\">Given the increasing global energy demand and under the premise of environmental protection, photovoltaic power generation will undoubtedly occupy an important place in global energy consumption in the 21st century.<\/p>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\">The DJSF1352-RN DC energy meter is mainly used for measuring and monitoring DC signal devices such as batteries on the DC side of the PV project.<\/p>","protected":false},"excerpt":{"rendered":"<p>In diesem Beitrag wird die Anwendung des Acrel DC-Meters in einer Photovoltaikanlage in Singapur beschrieben. Das Ger\u00e4t misst Strom, Spannung und Energie sowie den Shunt. Projekt\u00fcbersicht Dieses Unternehmen hat seinen Sitz in Singapur und ist das Unternehmen f\u00fcr die Installation von Photovoltaikanlagen in Singapur. Haupts\u00e4chlich verwendet DC-Energiez\u00e4hler DJSF1352-RN und Shunt, verwendet, um Strom und Spannung [&hellip;]<\/p>","protected":false},"author":2,"featured_media":456,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-658","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-asien"],"_links":{"self":[{"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/posts\/658","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/comments?post=658"}],"version-history":[{"count":7,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/posts\/658\/revisions"}],"predecessor-version":[{"id":739,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/posts\/658\/revisions\/739"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/media\/456"}],"wp:attachment":[{"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/media?parent=658"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/categories?post=658"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.acrel-electric.de\/en\/wp-json\/wp\/v2\/tags?post=658"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}