MID Certification Three-Phase DIN-Rail Energy Meter | |
Measurement accuracy: | kWh: Class 0.5 |
Frequency: | 45~65Hz |
Nominal voltage: | AC 3*230/400V(±20%) |
input current: | 80A, 120A, 200A, 300A, 3*80A, 3*120A, 3*200A, 3*300A |
Diameter of the transformer perforation: | 10mm, 16mm, 24mm, 36mm |
Active energy: | Class B (split current transformer) |
Reactive energy: | (Class 2 accuracy) |
Power consumption: | ≤2W |
Baud rate: | Supports 1200 bps-38400 bps |
Dimensions: | 90*45*65mm |
Operating temperatur: | -40℃~+70℃ |
Installation: | 35mm |
ADL400N-CT Three-phase DIN-rail energy meter
ADL series multifunctional electric energy meter mounted on DIN rail is an intelligent instrument mainly designed for new power generation systems such as grid-connected photovoltaic systems, micro inverter systems, energy storage systems, AC coupling systems, etc. The product has the advantages of high precision, small volume, high response speed and convenient installation. The product has the features of sampling, measuring and monitoring power parameters, communicating with inverter or energy management system (EMS), realizing the functions of preventing backflow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional measurement and distributed household photovoltaic energy management.
Product info
Technical data
Tension |
nominal voltage | AC 3*230/400V(±20%) | |||
consumption | <2W, <10VA | ||||
Accuracy class | Error ±0.5 % | ||||
Electricity | Input current |
AC 80A, 120A, 200A, 300A, 3*80A, 3*120A, 3*200A, 3*300A |
|||
Accuracy class | Error ±0.5 % | ||||
consumption | <1W, <1VA | ||||
Performance | Active, reactive, apparent power, error ±0.5 % | ||||
frequency of the grid | 50/60 Hz, error ±0.5 % | ||||
response rate |
≤100ms (voltage, current, power) | ||||
≤1s (electrical energy) | |||||
measurement category | CAT III | ||||
overvoltage level O | OVC III | ||||
Energy measurement |
Active energy: Class B | ||||
reactive energy (accuracy class 2) |
|||||
Measurement performance | accuracy | kWh Class 0.5 | |||
Area | 0~9999999999.99kWh | ||||
Beat | accuracy | Error ≤0.5s/d | |||
Active impulse | Width | 80±20ms | |||
communication |
interface | RS485 | |||
protocol | MODBUS-RTU:1~247 | ||||
baud rate |
1200bps-38400bps | ||||
Temperature range | Work | -40℃~+70℃ | |||
storage | -40℃~+70℃ | ||||
humidity | ≤95%(No condensation) | ||||
Altitude | <2000m |
reference standard |
EN IEC 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements EN IEC 61010-2-030:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment with test or measuring circuits EN IEC 61326-1:2021 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements EN IEC 61326-2-1:2021 Electrical equipment for measurement, control, and laboratory use - EMC requirements - Part 2-1: Particular requirements for electromagnetic compatibility testing for electrical equipment for measurement, control, and laboratory use EN 50470-3 Electricity measuring instruments (alternating current) - Part 3: Particular requirements - Static meters for active energy (class indices A, B and C) |
IP |
IP 51 (Must be installed in a suitable IP housing) |
degree of pollution | II |
UC degree | III |
installation environment | indoor use |
degree protect | Class II (double insulation) |
operating environment | Cabinet mounting (the outer shell cannot be touched) |
Mechanical quality | M1 |
Safety features of transformers |
Insulation resistance: more than 1000 MΩ under normal conditions; Electrical strength resistance: It can withstand a power frequency of 4000V and 50Hz for 1 minute; Flame retardancy: Complies with UL94-V0; |
Product display
Downloads
Video

similar products