Base station energy monitoring solution
The base station's machine rooms are primarily equipped with signal receivers, monitoring devices, fire extinguishers, power supplies, and air conditioning systems. Therefore, measuring and monitoring the electrical parameters and energy consumption on the AC side of the base station (e.g., mains power, diesel, air conditioning, lighting, power supply, etc.) and the electrical parameters and energy consumption of communication equipment, batteries, and other 48V power supplies within the base station are crucial. Furthermore, some scenarios require separate power consumption statistics for the communication equipment of different operators for the tower company's internal billing purposes. This data can be uploaded to the platform in real time via Acrel products with the RS485 interface to ensure the base station's security and power consumption.
• Mobile telecommunications • Telecommunications providers • Communication base station
1. Measurement: Multi-circuit voltage, current, power, energy, and other electrical parameters. 2. Communication: RS485 Modbus-RTU, NB, or 4G. 3. Certification: CE and IEC compliant. 4. Accuracy: 0.5 s or 1
-
Application
-
Application scenario
-
Main functions
-
structure
Electricity control, electricity theft monitoring
Monitoring of the base station's input and output circuits, real-time monitoring of the line's power consumption, and theft detection by determining maximum power usage and whether other devices are being accessed.
-
Diagram of the monitoring system for the power distribution of the base station
Statistics of the electricity bill
The electricity consumption data for the communication devices of the various operators in the base station are determined as a basis for the tower company's internal billing.
-
Topology diagram of energy consumption monitoring of the base station
Energy-saving control
Achieve energy savings for the base station by controlling the start and stop of the air conditioner, adjusting the working mode of the communication devices, or controlling the start and stop.
Advantages
-
DC power distribution monitoring of the base station: AMC16L-DETT:
Multi-loop DIN rail energy meter
General Surveillance & Mobile Communications & Telecom & Unicom & Broadcasting and other communication equipment
DC48V power supply
Maximum 6 DC loop accesses
Output 0-5V current Hall sensor access
With ±12V output for powering the Hall sensor
RS485 communication -
Monitoring of the DC distribution of the base station: DJSF1352-RN:
UL DC Energy Meter
General Surveillance & Mobile Communications & Telecom & Unicom & Broadcasting and other communication equipment
DC24V/48V AC/DC85-265V power supply
Maximum 2 DC loop accesses
Output 0-5V current Hall sensor or 75mV shunt access
With ±12V output for powering the Hall sensor
RS485 communication -
AC power distribution monitoring of the base station: AMC96L-E4:
Panel energy meter
Monitoring of mains power & diesel engine
Power supply AC/DC 85-265V
Direct access up to 660V 5A
4DI and 2DO
RS485 communication -
AC power distribution monitoring of the base station: DTSD1352-4S:
Multi-loop DIN rail energy meter
Monitoring of mains power, diesel engine, air conditioning, lighting, etc.
Power supply AC/DC 85-265V
Maximum 12 single-phase or 4 three-phase accesses
mA-level CT access (crystal head)
4 passive DI&1 DO&2 active DI
RS485 communication -
AC power distribution monitoring of the base station: ADL400:
MID three-phase DIN rail energy meter
Monitoring of mains power & diesel engine
Power supply AC/DC 85-265V
100A direct access or 5A CT access
RS485 communication -
AC power distribution monitoring of the base station: ADW300:
Three-phase DIN rail energy meter
Monitoring of mains power & diesel engine
Power supply AC/DC 85-265V
Direct access up to 660V 5A
4DI and 2DO
RS485 communication -
Monitoring of the DC distribution of the base station: AHKC:
Hall current sensor
Reconstruction project takes on an open type
New project adopts a closed type
0-5V output
±12V power supply
suggested products
projects