HomeProductsNew energyACR10R-D Series PV/Solar Energy Meter for InvertersACR10R-DxxT Bidirectional single-phase energy meter for reverse flow monitoring

ACR10R-DxxT Bidirectional single-phase energy meter for reverse flow monitoring

The ACR10R-DxxTE series single-phase AC energy meter for DIN rail mounting with split open current transformer terminals is suitable for power monitoring of grid-connected photovoltaic power plants, load control, and other applications. It is specifically designed for solar inverters and measures electrical parameters such as current, voltage, active power, reactive power, apparent power, frequency, power factor, etc. It supports multi-tariff and 4-quadrant energy metering, harmonic analysis, and energy monitoring. Remote signaling and remote control of circuit breakers are possible via digital inputs and relay outputs.

  • Measurement: 1-phase active power, reactive power, current, voltage, etc.
  • Rated current: up to 300 A (coupled with external current transformers)
  • Communication: RS485 (MODBUS-RTU)
  • Application: Use in decentralized solar systems and anti-reflux inverters
  • Display: LCD display
  • Dimensions: 54 x 74 x 85 mm (L x W x H)
  • Mounting: 35 mm DIN rail
  • Power supply: 85–265 V AC or 100–350 V DC
  • Standard and certificate: CE

Product info

accuracy
Voltage: 0.2, Current, Power, Active energy: 0.5, Frequency: 0.01 Hz, Reactive energy: 1

frequency
45–65 Hz

Power consumption
≤10 VAp>

Power supply output
AC 85-265V or DC 100-350V

Input power
Under 0.2 VA

Technical data

Features

Use in decentralized photovoltaics

● Backflow monitoring

● Harmonic monitoring

Bidirectional measurement

● Active energy measurement

● Reactive energy measurement

RS485 communication

● MODBUS-RTU protocol

● Communicate with the inverter to achieve the backflow prevention function

Single-phase two-wire connection

● Paired with external split current transformer

● Rated voltage: AC 100 V, 400 V

LCD display

● Parameter display

● Programming interface

Control panels and HMI for programming

● Parameter display

● Communication (address, baud rate, etc.)

 

Technical parameters

Indicators

 

 

 

 

 

Entrance

Phase line

Single-phase

frequency

45~65Hz

 

 

voltage

Rated voltage: AC 100 V, 400 V

Overload: 1.2 times rated voltage (continuous); 2 times rated voltage for 1 second

Power consumption: less than 0.2 VA

 

 

Electricity

Rated current: 10 A, 20 A, 40 A, 80 A, 120 A, 200 A, etc. (See product specifications for details)

Overload: 1.2 times rated current (continuous); 10 times rated current for 1 second

Power consumption: less than 0.2 VA

 

output

communication

RS485 interface, Modbus RTU

Advertisement

LCD

Measurement precision

Voltage: 0.2 steps, current, power active energy: 0.5 steps, 0.01 Hz frequency, reactive energy: 1 step

Power supply

AC85~265V or DC100~350V; power consumption ≤10VA

 

 

Security

 

Power frequency withstand voltage

AC2 kV 1 min between power supply // current input // voltage input and communication

AC2 kV 1 min between each combination pair of power supply, current input and voltage input.

Insulation resistance

Input, output connection to the housing >100MΩ

Environment

Operating temperature: -10 °C to +55 °C; Storage temperature: -20 °C to +70 °C

Relative humidity: 5 to 95 °C, non-condensing; Altitude: ≤ 2500 m

Product display