HomeProductsNew energyACR10R-D Series PV/Solar Energy Meter for InvertersACR10R-DxxTEx Bidirectional three-phase energy meter for reverse flow monitoring

ACR10R-DxxTEx Bidirectional three-phase energy meter for reverse flow monitoring

The ACR10R-DxxTE4 three-phase DIN rail energy meter with split open current transformer terminals is suitable for power monitoring of grid-connected photovoltaic power plants, load control, and other applications. It is easy and cost-effective to install without removing the primary rail. It measures electrical parameters such as current, voltage, active power, reactive power, apparent power, frequency, power factor, etc. It supports multi-tariff energy metering, 4-quadrant energy metering, harmonic analysis, and energy monitoring. Remote signaling and remote control of circuit breakers are possible via digital inputs and relay outputs.

  • Measurement: Three-phase active power, reactive power, current, voltage, etc.
  • Rated current: up to 300 A (with current transformers); up to 20,000 A (with Rogowski coil)
  • Communication: RS485 (MODBUS-RTU)
  • Application: Use in decentralized solar systems and anti-reflux inverters
  • Display: LCD display
  • Dimensions: 54 x 64 x 84 mm (L x W x H)
  • Mounting: 35 mm DIN rail
  • Power supply: 85–265 V AC or 100–350 V DC
  • Standard and certificate: CE

Product info

accuracy
Voltage: 0.2, Current, Power, Active energy: 0.5, Frequency: 0.01 Hz, Reactive energy: 1

frequency
45–65 Hz

Power consumption
≤10 VAp>

Power supply output
AC 85-265V or DC 100-350V

Input power
Under 0.2 VA

Technical data

Features

Use in decentralized and centralized photovoltaics

● Rogowski coils for centralized photovoltaics

● Split-core current transformer for decentralized photovoltaics

● Backflow monitoring

● Harmonic monitoring

Bidirectional measurement

● Active energy measurement

● Reactive energy measurement

RS485 communication

● MODBUS-RTU protocol

● Communicate with the inverter to achieve the backflow prevention function

Coupled with external current transformers or Rogowski coil

● Rated current of the current transformers: up to 300 A

● Rated current of the Rogowski coil: up to 20,000 A

LCD display

● Parameter display

● Programming interface

Control panel HMI for programming

● Parameter display

● Communication (address, baud rate, etc.)

● Wiring: 3P3W, 3P4W

 

Function/Model

ACR10RH-DxxT(R)E4 ACR10RH-DxxT(R)E3

display mode

LCD (Field LCD)

 

 

 

measurement parameters

Current/Voltage/Frequency/Power Factor

Active power/reactive power/apparent power

Four-quadrant measurement of electrical energy

Maximum demand

Metering of electrical energy with multiple tariffs

 

Power quality monitoring

Overall harmonic content

Subharmonic (2-31 times)

Data logging

Incident recording

display mode

alarm

Built-in clock

communication

RS485 interface

Optional feature (select one)

J(2DO)

A1+ (B1 or C1)
(4DI+2DO or 4DI+EP)*

K(4DI)

Pulse (2 channels)

A notice:
1. "■" is the default assignment function, "□" is the mapping function. The above device uses 1-channel RS485 communication by default.
2. The connection mode corresponds to A1/B1/C1 etc. in the selection function.
3. Pulse output and relay output cannot be selected at the same time.
4. If you select the event logging function, you need to configure the DI or DO port.

Technical parameters

Indicators

 

 

 

Entrance

Phase line

3-phase 3-wire, 3-phase 4-wire

frequency

45~65Hz

 

voltage

Rated power: AC 57.7V/100V (100V), 220V/380V (400V)

Overload: 1.2 times power (continuous); 2 times power/1 second

Consumption: <0.2 VA

 

 

Electricity

Rated power: 80 A, 120 A, 200 A, etc. (see specific product specifications, special parameters can be customized)

Overload: 1.2 times power (continuous); 10 times power/1 second

Consumption: < 0.2 VA

 

 

output

 

Electrical energy

Output mode: open collector optocoupler pulse, two-way output

Three-phase

Pulse constant: 4000, 8000 Imp/kWh

communication

RS485 interface, Modbus RTU protocol

display mode

LCD

 

function

 

Switch

Entrance

Four-way dry contact input

 

output

Output mode: two-way relay NO contact output

Contact capacity: AC 250V/3A, DC 30V/3A

Measurement accuracy

Frequency 0.05 Hz, reactive energy 1 class, other 0.5 class

Power supply

AC85-265V or DC100-350V; DC24V (±10 %); DC48V (±10 %)
Consumption ≤ 10 VA

 

 

Security

 

 

Power frequency withstand voltage

The power frequency withstand voltage between auxiliary power and switching volume output and current input and voltage input and communication and pulse output and switching volume input terminal is AC 2 kV 1 min.; The power frequency withstand voltage between auxiliary power and switching volume output and current input voltage input terminal is AC 2 kV/1 min.; The power frequency withstand voltage between communication and pulse output and switching volume input terminal is AC 1 kV/1 min.;

Insulation resistance

Input, output connection to the housing>100MΩ

Environment

Operating temperature: -10 °C to +55 °C; Storage temperature: -20 °C to +70 °C; Relative humidity: 5 °C to 95 °C (no condensation); Altitude: ≤ 2500 m

Product display