Data center is a place which gathers a large number of servers, storage devices, network equipment and supporting UPS, precision air conditioning and other IT equipment, is to realize the centralized processing, storage, transmission, exchange and centralized management of data and information service platform.
Data center power supply quality directly affects the safe operation of IT equipment, so the data center column header tank outlet and inlet line of power supply monitoring are very important, in addition, as the global available energy and reduced energy costs increase, how much more economical and efficient use of energy has become a duty-bound responsibility related to enterprises.
Project overview
According to the monitoring equipment requirements of the data center array cabinet, our company developed the AMC16-FAK48 data center monitoring device to realize the electrical parameters of multiple outgoing lines and the switching status of the incoming and outgoing lines, and achieve comprehensive monitoring. InnovIT AG is the largest data center manufacturer in Germany. This meter, which can monitor up to 48 single-phase AC outgoing circuits, is used together with Acrel's AKH-0.66-K-Φ10 split-core current transformer to meet customers' requirements for monitoring 39 circuits.
Features
AMC16Z is a multi-circuit AC current meter for DIN rail mounting that was specially developed to meet the requirements of increasingly precise power distribution in data centers. It is suitable for careful, all-round self-monitoring of final distribution systems.
● Specially developed for power management of servers in data centers
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd to 31st harmonic
● kWh class 0.5
● DIN35mm

structure

Photos on site

Summary
With the rapid development of data centers, the problem of energy consumption in data centers is becoming more and more prominent. Energy management, power supply and distribution of data centers have become important issues. An efficient and reliable power distribution system for data centers is an effective way to improve the power consumption efficiency of data centers and reduce the energy consumption of equipment. In order to realize the energy saving of data center, you must first achieve accurate monitoring of each power consumer, the load circuit and data center very much, the traditional measuring instruments can not meet the cost, size, installation, construction and other aspects of the requirements, so you must use applies to data center centralized monitoring requirement of the multi-loop monitoring device.
The AMC16M is specially designed for array cabinets in the data center. The application of this type of product has been thoroughly studied, and it is better than other systems in terms of function, performance, availability and economics.