| Modell | functional description |
| ADW600-M | Data acquisition and remote transmission (4G / Ethernet / WIFI) |
| ADW600-U | Voltage measurement and sampling |
| ADW600-I | Power measurement (forward and backward), four quadrants without power Voltage, current, power factor, frequency, active power, reactive power, apparent power Total harmonic content, subharmonic content (2nd to 31st) Active pulse output |
| ADW600-K | 4DI, 2DO |
| ADW600-TL | 12 channels for temperature measurement, 4 channels for residual current measurement |
ADW600 Multi-channel three-phase energy meter
The ADW600 multi-circuit power measurement module is primarily used for measuring the three-phase active power of low-voltage networks. It offers the advantages of small size, easy installation, and a wide range of functions. The product features a modular design, including voltage modules, current modules, switching module (DO), temperature measurement modules, and leakage current modules, among others. The modules are connected via Ethernet cables and support multi-module combinations. It is suitable for multi-circuit measurement scenarios in low-voltage networks, particularly for power supply upgrades.
Product info
Technical data
|
ADW600-U |
nominal voltage |
3×57.7/100V, 3×220/380V, 3×100V, 3×380V |
|
Voltage accuracy |
0.5% |
|
|
Reference frequency |
45-65 Hz |
|
|
Power consumption |
< 0.5 VA per phase |
|
|
ADW600-I |
Input current |
D10: 0.03-0.15(6)A, D16: 0.8-2(100)A, D24: 3.2-8(400)A, D36: 4.8-12(600)A |
|
Accuracy of active energy |
Class B |
|
|
Energy pulse width |
80±20ms |
|
|
Active pulse constant |
D10: 6400 imp/kWh, D16: 400 imp/kWh, D24: 100 imp/kWh, D36: 60 imp/kWh |
|
|
Power consumption |
<1VA per phase |
|
|
ADW600-K |
Switch input |
4 passive channels, integrated 12V DC power supply |
|
Switching output |
2 passive channels, capacity AC 230 V/DC 30 V, 3 A |
|
|
ADW600-TL |
Temperature measurement |
12-channel temperature measurement, accuracy ±2 °C, 12 temperature measuring leads as standard |
|
Fault current measurement |
4-channel residual current measurement, maximum input current 1 mA, accuracy 1 %, residual current transformer must be purchased separately. |
|
Temperature range |
operating temperatur |
-25 ℃ ~ 55 ℃ |
|
Storage temperature |
-40 ℃ ~ 70 ℃ |
|
|
humidity |
≤95% (no condensation) |
|
|
Height |
<2000m |
|
Wiring instructions
|
The ADW600 multi-channel measurement module is connected via Ethernet cables. BUS-IN is the input interface and BUS-OUT is the output interface. Connect them from the ADW600-M or Power Module as a starting point and proceed in sequence. Do not connect in reverse order. The ADW600-U should be connected to the load voltage signal. See the wiring diagram below. Connect the voltage signals from UA, UB, UC, and UN to terminals 11-14. If using a three-phase, three-wire connection, connect the voltage signals from UA, UB, and UC to terminals 11-13. Then short UB to the UN terminal.
|
![]() |
| The ADW600-I should be connected to the load current signal. See the wiring diagram. The standard transformer is an RJ12 interface that can be inserted into the measurement terminals. Simply place the three transformers on the load cables according to the indicated directions. | ![]() |
| The ADW600-K connects to switch input or output signal lines as needed. Please note that the COM port is the common terminal. See the wiring diagram below. | ![]() |
| The ADW600-TL connects to either the temperature measurement signal line or the residual current transformer signal line as needed. Note that the COM port is the common connection for adjacent measurement circuits. | ![]() |