| IoT Wireless Energy Meter | |
| Measurement: | 3-phase voltage, current, power, power factor, etc. |
| Measurement accuracy: | Active power: Class 0.5S |
| Nominal voltage: | AC 3×220/380V,3×230/400V |
| Rated current: | AC 3x1(6)A |
| Frequency: | 50/60Hz |
| Pulse output: | Constant: 6400imp/kWh; 400imp/kWh |
| Consumption: | <1VA(single phase) |
| Dimensions: | Panel: 82*87.8*71.5mm |
| Starting current: | 2‰ln |
| Application: | Building, Factory, Smart Grids, DB Space and etc |
ADW300 IoT Wireless Energy Meter
The ADW300 new wireless smart energy meter is primarily used to measure the three-phase electrical active energy of low-voltage networks. With RS485 communication and LoRa 470MHz wireless communication capabilities, our ADW300 4G smart electricity meter offers users convenient access to monitor, collect, and manage their electricity consumption.
Product info
Technical data
| Model | ADW300-4G | ADW300-LR | ADW300-LW | ADW300-WF |
| Voltage input | nominal voltage | 3×57.7/100V,3×220/380V,3×380/660V,3×100V,3×380V,3×660V |
| Reference frequency | 50Hz | |
| consumption | <0.5VA (Each phase) | |
| Power input | Input current | 3×1(6)A;3×1(6)A(ADW300w),3×20(100A)(ADW300W) |
| Starting current | 1%. Ib(Class 0.5S),4% Ib(Class 1) | |
| consumption | <1VA (Each phase) | |
| Relief supplies | Power supply | AC85~265V |
| Power consumption | <2W | |
| Measuring performance | default | IEC62053-22:2003,IEC62053-21:2003 |
| Effective work accuracy | Class 0.5S (ADW300), Class 1(ADW300W) | |
| Temperature Accuracy | ±2℃ | |
| pulse | Width of the pulse | 80±20ms |
| Impulse constant | 6400imp/kWh, 400imp/kWh | |
| communication | Wireless | 4G, WiFi, LoRa, LoraWan |
| Infrared interface | The constant baud rate is 1200 | |
| RS485 interface | RS485(A,B) | |
| Connection mode | Shielded twisted pair cables | |
| protocol | MODBUS RTU |
| Functions | |
| display mode | LCD |
| Energy measurement | Active kWh (positive and negative), quadrant reactive power energy |
| Electrical measurement | U、I、P、Q、S、PF、F |
| Harmonic function | THDv、Harmonic on 2nd and 31st |
| Three-phase unbalance degree | Voltage asymmetry, current asymmetry |
| Measuring the temperature | Temperature of A/B/C/N (alternative configuration: T) |
| Leakage current | 1 channel differential current measurement |
| TUE/THU | 4DI,2DO(Alternative configuration.K) |
| External current transformer | External open current transformer (alternative configuration: W) |
| Electrical Parameter Alarm | Undervoltage, undercurrent, overcurrent, underload, etc. |
| communication | Infrared communication |
| RS485(Alternative configuration: C) | |
| LR-LoRa: 470MHz | |
| LW-LoraWan: 433MHz, 915MHz, 923MHz | |
| GPRS (alternative configuration: 2G) | |
| 4G/4GHW(Alternative configuration: 4G) | |
| WiFi(Alternative configuration: WiFi) | |
| Step ①: Correct Installation&Wire Meter | ![]() |
| Step ②: Download and register IoT APP | ![]() |
| Step ③: Add counters to your account | ![]() |
| Step ④: Start your 3-month free trial | ![]() |
Product display