HomeProductsEnergy managementADW Series IoT Energy MeterADW210 Wireless multi-circuit energy meter

ADW210 Wireless multi-circuit energy meter

ADW210 Wireless Multi Circuits Energy Meter is mainly used for measuring the complete electrical parameters of multiple three-phase circuits, which can be connected to up to four three-phase circuits with one main module.Can directly or indirectly measure voltage and current, power, power factor, phase angle, unbalance degree, harmonics and other parameters.Optional switch 8DI4DO, temperature 12NTC, leakage current 4L and wireless communication module.

  • Monitors up to 4 circuits 3-phase or 12 circuits 1-phase
  • Monitors all electrical parameters
  • Split core open loop current transformer
  • External function module, such as MK (switching inputs and outputs), MTL (temperature and leakage current measurement), AWT100 (wireless communication)
  • LCD display
  • CE certificates

Product info

IoT Wireless Energy Meter
Measurement accuracy:Active energy: Class 1.0
Reactive power: Class 2
Frequency:50/60Hz
Pulse output:Active pulse output and reactive pulse output
Wireless communication:4G(Global General Module), WiFi, LoRa, LoraWan
Dimensions:Screen size (L×W×H):
72*97.7*36mm
Starting current:4‰lb
Installation:35mm
consumption<0.5VA(single phase)

Technical data

parameter

Description&Value

Auxiliary energy

 

AC/DC 85~265V; Power consumption≤10VA;

input

 

frequency

45~65Hz

Tension

AC3×220V/380V;

Overload: 1.2 times rated value (continuous); 2 times rated value / 1s;

Power consumption: ≤ 0.5VA;

Current

AC 5A、100A、400A、600A;(External opening transformer); Power consumption: ≤ 0.5VA;

Overload: 1.2 times rated value (continuous); 10 times rated value / 1s;

Measurement accuracy

Frequency 0.05Hz, voltage、current class 0.5; Accuracy of 2nd-31st harmonic: ± 1%;

 

Active electrical energy level 1, reactive electrical energy level 2;

Characteristics

Pulse output

Output mode: open collector optocoupler pulse;

communication

RS485、Modbus RTU; Baud rate 1200~38400;

Switching input

Dry contact input、Built-in power supply;

Switching output

Output mode: relay normally open output; switching capacity: AC 250V/3A DC 30V/3A;

Optional module

External Module (MTL)
12 External NTC temperature measurement
4-channel residual current measurement
External wireless module (AWT100)
Downlink RS485; Uplink 4G, 2G, LoRa, LoraWan, Ethernet, WiFi, GPS, Profibus
External Module (MK)
12-channel DI-4-channel DO

Product display